SMART ODME – Oil Discharge Monitoring Equipment

The Oil Discharge Monitoring Equipment (SMART ODME) is a slop water monitor for tankers.

The SMART ODME has been designed to provide means of monitoring, recording and controlling the ballast discharge for crude oil, product and chemical tankers including ICE class vessels.

This system is modular in construction and does not require the usual pump/motor bulkhead penetration as used on older systems.

The SMART ODME includes all components required to meet MEPC 108(49) and the latest MEPC 240(65) for bio fuels, effective 1 January 2016.

The SMART ODME incorporates a ‘simulation mode’ to aid system demonstration to PSC surveyors and is designed for ease of retrofitting, operation, installation and maintenance. Discharge limits are set at 30 litres of oil per nautical mile or 1/30,000 of the previous cargo for slop and wash water discharges.

The Oil Discharge Monitoring Equipment (Smart ODME) has been designed to provide means of monitoring, recording and controlling the ballast discharge for crude oil, product and chemical tankers including ICE class vessels.

This system is modular in construction and does not require the usual pump/motor bulkhead penetration as used on older systems. The Smart ODME includes all components required to meet MEPC 108(49) and the latest MEPC 240(65) for Bio Fuels, effective 1 January 2016.

The Smart ODME incorporates a ‘simulation mode’ to aid system demonstration to PSC surveyors, is designed for ease of retrofitting, operation, installation and maintenance.

Discharge limits are set at 30 litres of Oil per nautical mile or 1 / 30,000 of the previous cargo for slop and wash water discharges.

Smart ODME

  • The SMART ODME has been Biofuel Approved in accordance with MEPC.240(65)
  • The system has been designed for an easy installation at the yard with only one flow meter and one sample point
  • Minimal bulkhead penetration with motor and pump in one location.
  • Paddle wheel flow sensor making for simple installation and maintenance
  • Calibration Check Kits available for functional testing
  • Fleet Deals – Frame Agreements & Exchange Schemes
  • Slop Water Discharge
  • Tank Wash Water Discharge
  • Clean Ballast Water Discharge
  • The SMART ODME has been designed in a modules to allow for integration into bespoke ship designs.
  • Pneumatic or electric sample pump options
  • Fleet Deals – Frame Agreements & Exchange Schemes
MEASUREMENT  
Oil types: As Per MEPC 108(49) + MEPC 240(65) requirements
Clean water calibration: Automatic
Oil measurement range: 0 – 1000 ppm all types
Resolution: 1 ppm
Accuracy oil + solids: As Per MEPC 108(49) requirements
DATA STORAGE AND RETRIEVAL  
Data retrieval: via LCD display or download to PC using HyperTerminal or Rivertrace IMO Log downloader programme
ENVIRONMENTAL & SAMPLE
Sample Pressure Range 0.1bar to 5bar
Sample Flow Rate 4Lpm to 5Lpm
Sample Temperature 1⁰C to 40⁰C
Ambient Temp Range -20⁰C to 50⁰C
Hazardous Area VPC is Group II Zone 1G IIB T4
SYSTEM AND SUPPLY  
Supply voltage: 115 / 230V ac, 50 – 60Hz (Switchable)
Zener Barrier/Computer Module: 115 / 230V ac, 50 – 60Hz (Switchable)
Motor: 380-440V ac, 50-60Hz, 3 phase, 250W
Supply voltage Consumption: < 50 VA Single Phase
Approvals: MEPC 108 (49) – DNV, USCG, CCS and NKK.
MEPC 240(65) – DNV, CCS and NKK

 

This system may be installed in line with any new and existing IMO MEPC 60(33) and 107(49) approved monitors.

Specifications and system descriptions accurate at time of publishing. These are subject to change.

To ensure the highest precision and reliability of your equipment we highly recommend Annual Calibration.

If your device is registered with the Rivertrace portal, you can request a Calibration Check via the portal.

 SMART ODME has a number of service options depending on your company requirements. They are listed below:

 

Calibration option 1 – Self Annual Calibration Check

  • Crew can conduct an annual verification of the system using the Part Number 112777 SMART ODME CALIBRATION CHECK WATER SAMPLE (225mL bottle of 500 PPM) and follow this procedure – SMART ODME Calibration Check Procedure

 

Calibration option 2 – Rivertrace Engineer Annual Calibration Check

 

Calibration option 3 – Exchange Process Calibration Check

  • The last option is to set up an exchange process whereby you can buy a new measuring cell which will come with a new 5 year factory calibration certificate which can be exchanged by the crew and the old measuring cell can be returned to Rivertrace for recalibration. More information can be found here Smart ODME measuring cell replacement

 

Please contact us to discuss service requirements or to customise your monitoring solutions.

Please use this page to identify the part number of the part that you require.

Main Spare Parts

ODME Fuse Kit

Set of required voltage fuses – Part number 109520

ODME Fuse Kit
Fuse single

ODME O-Ring Kit

Selection of 4 O Rings in required sizes – Part number 109521

ODME Ring Kit 109521

Coil 24 Vol

Part number 109575

Coil 24v 109575

Serial USB – RS232 Cable

Part number 109631

Serial to USB 2
Serial to USB Cable 109631

Serial Data Cable

Part number 109632

Serial Cable 2
Serial Cable

Autoclean Wiper Small Tube

Part number 106815

Auto clean wiper

Spare Rotor Kit for GF Signet Flowmeter Type 525-2 – Parts 105958 & 110486 (St Steel Pin)

Part number 110487

Spare Rotor Kit for GF Signet Flowmeter Type 525-2

Cell Brush – BU455-17

Part number 111002

Spare Rotor Kit IN PVDF (mag rotor and shaft) for Type DP490 Flowmeter

Part number 111320

Spare Rotor Kit IN PVDF

Smart ODME Cell Assembly ***

Part number 109187

Smart Cell ODME

Smart ODME Cleaning Kit

Part number 111023

Smart ODME Cell Cleanking Kit

Oil discharge monitoring

Oil discharge monitoring is a crucial component for efficient operation on board ships, ensuring compliance with the stringent MEPC.108(49) marine environmental regulations. These guidelines mandate the use of advanced Oil Discharge Monitoring and Control Systems on tankers. This oil discharge monitoring equipment is essential for tracking the oil content in slop water discharged into the sea.

By maintaining precise monitoring, ships can efficiently manage oil discharge, minimising environmental impact and adhering to international pollution standards.

The integration of these systems supports automatic data recording, which aids in regulatory audits and reporting processes. Furthermore, by preventing any discharge above regulated limits, these systems help avoid costly penalties, thus preserving the vessel’s operational integrity.

Efficient oil discharge monitoring not only safeguards marine ecosystems but also aligns with sustainable shipping practices, contributing to the overall operational efficiency and eco-friendliness of maritime activities.

If you have any questions about the MARPOL marine environmental regulations or the Marine Environment Protection Committee (MEPC) guidelines, please contact us either by submitting a form here using this link with your questions or email us at sales@rivertrace.com. We are always happy to help.

For more information on the MARPOL marine environmental regulations or the Marine Environment Protection Committee (MEPC) guidelines visit our Regulations section

See our latest technology products here

Our services

The services we offer are focused on keeping your oil detection sensors and water monitoring systems running effectively to provide accurate data and timely alerts.

  • Calibration Services
  • Repairs and Replacements
  • Technical Support
  • System Diagnostics  
support 1 1