Smart ESM – Scrubber Washwater Monitor

The SMART ESM is a washwater monitor for wet scrubber systems measuring and recording PAH, Turbidity, Temperature and pH.

In January 2020, the IMO 2020 global sulphur cap came into force to improve air quality, preserve the environment and protect human health. To comply with this sulphur reduction a popular solution is to install an exhaust gas cleaning system (EGCS).

In January 2020, the IMO 2020 global sulphur cap came into force to improve air quality, preserve the environment and protect human health. To comply with this sulphur reduction a popular solution is to install an exhaust gas cleaning system (EGCS).

For this, wet scrubber systems use wash water to remove the pollutants from the exhaust gas. Therefore the wash water being discharged must be monitored at all times to ensure it is within the limits set by the regulating body. There are IMO regulations for water quality parameters including Polycyclic Aromatic Hydrocarbons (PAHs), pH and turbidity prior to discharge into the ocean.

With over 35 years experience designing equipment for the marine environments, Rivertrace has developed our SMART ESM. The SMART ESM designed to MEPC.259(68) and MEPC.340(77) and is suitable for both the inlet and outlet of a EGCS, measuring and recording the required parameters of PAH, Turbidity, Temperature and pH. The monitor can be installed on new build of retrofit systems and can accommodate open-loop, closed-loop and hybrid scrubber systems.

The innovative measuring cell design allows for unique Plug and play maintenance design. Each measurement parameter is enclosed in a separate cassette slotted inside the measuring cell around the sample tube. This allows the calibrated parts to be swapped without the need of isolating the sample which flows through a glass tube in the centre of the cell.

SMART ESM – Frame Mounted (FM) Configuration with Sample Heat Exchanger and Motor Pump

SMART ESM – Box Mounted (BM) Configuration with Sample Heat Exchanger and Motor Pump

  • Compatible with Open Loop, Closed Loop and Hybrid systems
  • Flexible configuration at each sample point for the relevant measurement parameters – PAH, pH, Temperature and Turbidity
  • Suitable for inlet and outlet monitoring
  • Plug and play design for each measurement parameter for easy maintenance
  • Calibration Check Kits available
  • On screen historical data graphs showing Instant/ Hourly/Daily/Weekly figures
  • Automatic cleaning of optical path
  • Exhaust Scrubber Washwater Discharge
  • MEPC 259(68)

At Rivertrace we understand every EGCS is different, and we can tailor our system to accommodate the specific parameters and requirements for the scrubber and vessel.
We offer 2 main designs for our equipment which can be customised further with additional components based on technical requests.

Option 1 – Frame Mounted. This option is based on a modular design all mounted onto a frame / backplate. It consists of a cooled cabinet housing the Control Module and Measuring Cell with a separate enclosure for the electronics.

Option 2 – Box Mounted. This option is based on a twin enclosure design.
It consists of a cooled cabinet housing the Control Module and electronics and a separate compartment for the Measuring Cell and sample conditioning equipment.

Other optional components include:

  • Sample Heat Exchanger should be included is the sample temperature is above 40degC
  • Motor / Pump should be included if the pressure in the sample line is below 0.5bar
PAH Range 0μg/L to 4500μg/L
PAH Accuracy 5% of measurement reading
PaH Measurement Principle UV Fluorescence
Turbidity Range 0 – 500 NTU
Turbidity Accuracy 0.1NTU up to 100 NTU, 1NTU thereafter.
Turbidity Measurement Principle IR Scattering
pH Range 0 – 14 pH
pH Accuracy 0.1 pH
pH Measurement Principle pH Electrode
Sample / Clean Water Temperature range 0oC to 40oC*

*Higher optional with Heat Exchanger

Sample / Clean Water pressure range 1 to 9 Bar
Optimum Measuring pressure (Sample / Clean) 3 Bar
Required Air Supply Pressure Range 4 – 6 Bar
Compressed Air normal / average consumption 450mL / Hr
Sample / Clean Water Flow rate range 1 to 4 LPM
Ambient Temperature range 0°C to 50°C
Supply Voltage 230 VAC 50/60 Hz
Outputs MODBUS

4-20mA

Response Time 266 seconds at 1l/m flow rate
Storage Internal SD Card

Downloadable to External USB

IP Rating IP66
Wetted Parts Material uPVC, Nylon, Black acetal copolymer and peek
Approvals DNV Type Approval – MEPC.259(68) and MEPC.340(77)

To ensure the highest precision and reliability of your equipment we highly recommend Annual Calibration.

If your device is registered with the Rivertrace portal, you can request a Calibration Check via the portal.

Calibration option 1 –  Annual Calibration Check

  • Annual Calibration Check – This would require the Calibration Check Kit (109996) our Rivertrace Approved Engineer would perform a calibration check and issue an annual certificate.

  • Calibration Kit Required – To conduct an annual calibration check, the Calibration Check Kit (Part No:  109996) is necessary.

  • Certified Engineer Services – A Rivertrace Approved Engineer will administer the calibration check.

  • Certification – Following the successful calibration, an annual certification will be issued.

Calibration option 2 – IMO 5 Year Calibration

  • IMO 5 Year Calibration – Measuring Cell Replacement (109171) this comes with the 5-year factory calibration certificate.

Calibration option 3 – Complete Manufacturer’s Calibration Process

  • Return your unit to Rivertrace – Please send your unit back to us to fulfill the calibration process and ensure your equipment is operating with optimal precision.

Please contact us to schedule your annual calibration check and maintain your equipment’s optimal performance

Service Options – SMART Bilge

  • Fault Diagnosis and Repair – Comprehensive troubleshooting to identify and fix issues.

  • Installation and Upgrades – Seamless setup and enhancement of your monitoring equipment.

  • Optional Add-Ons Available – Choose additional features such as Flow Switch and Autoclean.
  • Servicing – Fault Finding/Repair or installation /upgrades to the monitor with optional extras are available (flow switch & autoclean).

Please contact us to discuss service requirements or to customise your monitoring solutions.

Please use this page to identify the part number of the part that you require.

SmartBilge assembly overview

To ensure the correct parts are purchased, the serial number and voltage of your SmartBilge should always be provided to Rivertrace when ordering spares.

Standard Smart Bilge
Standard Smart Bilge
Smart Bilge with Autoclean and flow switch
Smart Bilge with Autoclean and flow switch

Main Spare Parts

When purchasing a replacement controller PCB, it is important to state any special settings that may be required from the list below:

  • 5ppm Maximum alarm set-points
  • Autoclean  enabled
  • Flow switch enabled

If no special settings are required, the standard software settings shall be applied that consist of the following:

  • 15ppm Maximum alarm set-points
  • No Autoclean capability
  • No flow switch capability

Installation instructions for your replacement controller PCB can be found here.

Installation instructions for your replacement controller PCB can be found here.